Choose The Modal Shop as your partner in an accurate, controlled and confident transducer calibration program. Please refer to our Scope of Accreditation for TMS A2LA accredited service scope and uncertainties.
Simply email info@modalshop.com or call 800.860.4867 (toll free domestic) or +1.513.351.9919 (international) to arrange a return material authorization (RMA) number and
include this number on your incoming package and paperwork.
Calibration Services
The following services ensure accurate data and provide a calibration certificate.
Vibration Accelerometers
Model | Description |
---|
MCS‑A001‑A004 | Calibration of accelerometer, single axis amplitude and phase response from 0.5 Hz to upper 5% frequency, NIST traceable. A2LA accredited. |
MCS‑A001‑A004T | Calibration of triaxial accelerometer, amplitude and phase response from 0.5 Hz to upper 5% frequency, NIST traceable. A2LA accredited. |
MCS‑A010 | System calibration for calibration standard system. Frequency sweep from 5 Hz to 10 kHz, NIST traceable. A2LA accredited. |
MCS‑35 | Single axis high frequency amplitude and phase response calibration from 5 Hz to 20 kHz. NIST traceable. A2LA accredited. Includes sensor bias measurement (for ICP® sensors) and resonant frequency sweep up to 50 kHz. |
MCS‑35T | Triaxial high frequency amplitude and phase response calibration from 5 Hz to 20 kHz, NIST traceable. A2LA Accredited. Includes sensor bias measurement (for ICP® sensors) and resonant sweep up to 50kHz. |
MCS‑A001 | Calibration of accelerometer, single axis amplitude and phase response from 5 Hz to upper 5% frequency, NIST traceable. A2LA accredited. |
MCS‑A001T | Calibration of accelerometer, triaxial amplitude and phase response from 5 Hz to upper 5% frequency, NIST traceable. A2LA accredited. |
MCS‑A065 | Primary accelerometer calibration service, using laser interferometry per ISO 16063-11 from 5 Hz to 20 kHz at up to 45 specific, user defined frequencies. A2LA accredited. |
MCS‑A067 | Single point primary accelerometer calibration via laser interferometer at 100 Hz. A2LA accredited. |
Shock Accelerometers
Model | Description |
---|
MCS‑31 | High g accelerometer calibration using PneuShockTM to max 10,000g range at 5 amplitudes. NIST traceable. A2LA accredited. |
MCS‑31T | High g accelerometer calibration for triaxial sensor using PneuShockTM to max 10,000g range. NIST traceable. A2LA accredited. |
'
Microphones and Acoustic Instruments
Model | Description |
---|
MCS‑1 | Calibration of 130 series array microphone and preamplifier pair, NIST traceable. |
MCS‑2 | Calibration of standard precision condenser microphones, NIST traceable.A2LA accredited. |
MCS‑6 | Certification of precision microphone preamplifiers, NIST traceable. |
MCS‑9 | Calibration of precision microphone/preamplifier pair, NIST traceable. A2LA accredited. |
Handheld and Portable Calibrators
Model | Description |
---|
MCS‑A009 | Calibration of handheld calibrator, models 394C05, 394B06, and 394C06 or similar. NIST traceable. |
9100‑CAL01 | Calibration of 9100 Series Portable Vibration Calibrator. NIST traceable.A2LA accredited. |
MCS‑4 | Calibration of pistonphone, NIST traceable. |
MCS‑56 | Calibration of speakerphone, NIST traceable. |
Signal Conditioners and Electronics
Model | Description |
---|
MCS‑A047 | Calibration of USB signal conditioner 485B36 2 channel and equivalent, NIST traceable. |
MCS‑E003 | Calibration of 480 series (480C, 480C02, 480D, & 480D02), model 478A01, and equivalent models, NIST traceable. A2LA accredited. |
MCS‑E004 | Calibration of 480 series (480E06, 480E09, 480D06, & 480D09) and equivalent with multiple gain x1, x10, x100, NIST traceable. A2LA accredited. |
MCS‑E005 | Calibration of models 482A, 482A06/B06, 482A05/B05, 482A04, 482A21, 482A22, and equivalent, NIST traceable. A2LA accredited. |
MCS‑E010 | Calibration of series 481, models 533, 583, 584, 478A16, 478A17 & other various 16-channel signal conditioner, NIST traceable. A2LA accredited. |
MCS‑22 | Calibration Service for National Reliability VB Analyzers |
ERC‑1 | Standard Recalibration 422E series in-line Charge Amplifier. A2LA accredited. |
Impulse Hammers and Force Sensors
Model | Description |
---|
MCS‑H002 | Calibration of 086 series instrumented hammer or similar, NIST traceable. A2LA accredited. |
MCS‑H003 | Calibration of 288 series Impedance Head, NIST traceable. A2LA accredited. |