Mini SmartShaker™ with Integrated Amplifier

General Vibration Testing | Models K2004E01 and K2007E01

This electrodynamic exciter is a small, portable permanent magnet shaker with a new generation of ultra compact precision power amplifier integrated in its base. The revolutionary SmartShaker™ design eliminates the need for a separate, cumbersome power amplifier - just plug the excitation signal from a dynamic signal analyzer or function generator directly into the BNC on the base of the shaker. The unit is supplied with a DC power supply but can be run directly from any 12-21 VDC supply.

CE| UKCA

Highlights

  • Integrated power amplifier eliminates the need for a separate, cumbersome power amplifier
  • SmartShaker™ provides up to 7 lbf (31N) pk sine force with up to 1/2 in (13 mm) stroke
  • 10-32 threaded mounting insert supports payloads up to 2 lb (0.907 kg)
  • Trunnion mounting base with EasyTurn™ handles

Applications

  • General vibration testing
    • Small components
    • Sub-assemblies
    • Biomedical
  • Experimental modal analysis
  • Educational laboratory research
  • Mechanical impedance measurements

Specifications

View Datasheet  |   View Shaker Family Datasheet

 K2004E01 KitK2007E01 Kit
Force Rating – lbf (N)4.5 (20)7 (31)
Max Frequency – Hz [1]11 0009 000
Max Stroke – in (mm) pk-pk0.2 (5)0.5 (13)
Shaker Model2004E2007E
Amplifier ModelIntegratedIntegrated
Accessories Included

[1] Load dependent

Accessories

ModelDescription
Included
K2007E01-PSPower supply, 60 W, 19 V DC output, 100-240 V AC input
2110G06Nylon Stinger kit, 10-32 thread, pack of three
Suggested
PCB 288D01ICP® impedance head driving point sensor

The SmartShaker™ features an extremely rugged suspension systems using carbon fiber composite leaf armature flexures, avoiding the suspension damage common with some other small shakers. Isolated linear bearings provide low distortion and eliminate the need for reaction wrenches when mounting loads to the armature. A trunnion base with EasyTurn™ handle allows for convenient mounting and positioning. The exciter is delivered with a variety of 10-32 nylon stingers which provide electrical isolation from and flexible attachments to test articles.

Overview and quickstart guide for the SmartShaker Integrated Power Amplifier